| Gas | Formula |
|---|---|
| Acetylene | C2H2 |
| Ether | C4H10O |
| Alcohol | e.g. C2H6O |
| Ammonia | NH3 |
| Petrol | |
| Butane | C4H10 |
| Chloroform | CHCl3 |
| Hydrogen chloride | HCl |
| Helium | He |
| Carbon dioxide | CO2 |
| Carbon monoxide | CO |
| Methane (natural gas) | CH4 |
| Neon | Ne |
| Propane | C3H8 |
| Oxygen | O2 |
| Carbon tetrachloride | CCl4 |
| Toluene | C7H8 |
| Hydrogen | H2 |
| Xylene | C8H10 |
| Sensor inputs: | 8 two-or-three-wire sensors (e.g. LCTR 903) with current interface, 4–20 mA |
| Sensor supply: | 24 V= / 200 mA |
| Ranges: | CO 0-300 ppm NO2 0-30 ppm CH4 0-100 % UEG CO2 0-10 Vol % other ranges on request |
| Ambient temperature: | -10 °C to +40 °C |
| Digital inputs: | 1 input for siren cancel |
| Digital outputs: | max. 12 alarms 1 fault relay 1 siren relay Warning banner relay All outputs have floating change-over contacts, max. rating 250 V / 4 A |
| Standard output signals: | Analog output 4–20 mA serial interface RS 232 |
| Mains connection: | 230 V / 50 Hz 115 V / 60 Hz (optional) 24 V / DC (optional) |
| Dimensions (WxHxD): | 240 x 160 x 90 mm |
| Weight: | approx. 2 kg |
| Protection type: | IP 54 according to DIN 40050 |